JCP ETA Option 1 Ankerbolts, Hexagon Head

8 - 16mm dia. (80 - 200mm) Carbon steel, bright zinc plated (16mm mechanical galvanised)
JCP ETA Option 1 Ankerbolts, Hexagon Head
ETA Option 1 hex head Ankerbolt · ETA Option 1 hex head Ankerbolt

We supply JCP ETA Option 1 hexagon head Ankerbolts in bright zinc plated steel from 8mm to 16mm drill size, lengths 80mm to 200mm, assessed for cracked and non-cracked concrete with fire resistance loading listed by JCP; the 16mm rows are mechanical galvanised. The screwbolt action cuts its own thread - no expansion, fully removable.

Also known as: eta hex ankerbolt, approved concrete bolt.

ETA Option 1 hex head Ankerbolt dimensions

Drill diameter (d0)Order codeLength (L)Max fixture thicknessMin hole depth (h1)Across flatsInstallation torque (Nm)
8 mm JAB08/10075ETA 80 mm 5 mm 90 mm 15 mm 40
8 mm JAB08/10100ETA 100 mm 25 mm 90 mm 15 mm 40
8 mm JAB08/10130ETA 130 mm 55 mm 90 mm 15 mm 40
8 mm JAB08/10150ETA 150 mm 75 mm 90 mm 15 mm 40
10 mm JAB10/12100ETA 100 mm 15 mm 100 mm 17 mm 60
10 mm JAB10/12130ETA 130 mm 45 mm 100 mm 17 mm 60
10 mm JAB10/12150ETA 150 mm 65 mm 100 mm 17 mm 60
12 mm JAB12/14100ETA 100 mm 5 mm 110 mm 19 mm 80
12 mm JAB12/14130ETA 130 mm 35 mm 110 mm 19 mm 80
12 mm JAB12/14150ETA 150 mm 55 mm 110 mm 19 mm 80
12 mm JAB12/14200ETA 200 mm 105 mm 110 mm 19 mm 80
14 mm JAB14/16130ETA 130 mm 20 mm 130 mm 24 mm 90
14 mm JAB14/16150ETA 150 mm 50 mm 130 mm 24 mm 90
14 mm JAB14/16200ETA 200 mm 90 mm 130 mm 24 mm 90
16 mm JAB16/18150ETA 150 mm 30 mm 145 mm 27 mm 100
16 mm JAB16/18200ETA 200 mm 80 mm 145 mm 27 mm 100

Materials & strength

Certification

European Technical Assessment ETA-15/0040, Option 1 (cracked and non-cracked concrete). Certificates are available on request.

Material & finish

Carbon steel, bright zinc plated; 16mm sizes mechanical galvanised to minimum 40 microns.

Related specifications
Frequently asked

When is the assessed hex head range required?

Where the fixing schedule calls for an anchor with a European Technical Assessment - typically structural brackets and fixings whose failure would matter - in cracked or non-cracked concrete. For general-purpose work the standard hex head range covers the same sizes.

Need ETA Option 1 hex head Ankerbolt in a non-standard size or material?

Send us your drawing — specials quoted within 24 hours.

Send us your drawing